Density Test Report

Date :02/05/2024
Project No :2023C141
Client Company :Toll Bros
Arrival Time :02/05/2024 11:30
Onsite Hours :03:30
Name of the Project :N. Gate - Old Atlanta Road
Project Location :Cumming
Weather :sunny
Departure Time :02/05/2024 15:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
02/05/2024 1 17.4 103.1 24468 111.3 17.5 92.6 90 D6938 Pass
Location : Creek crossing , Elv/Depth :7 feet below finished grade
Comment : Gauge Serial No. :85758
02/05/2024 2 15.5 101.6 24468 111.3 17.5 91.3 90 D6938 Pass
Location : Creek crossing, Elv/Depth :5.5 feet below finished grade
Comment : Gauge Serial No. :85759
02/05/2024 3 15.1 102.0 24468 111.3 17.5 91.6 90 D6938 Pass
Location : Creek crossing, Elv/Depth :8 feet below finished grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, February 5, 2024
Reviewer Name / DateKenneth Mosman, March 11, 2024