Density Test Report

Date :02/14/2024
Project No :2023C141
Client Company :Toll Bros
Arrival Time :02/14/2024 8:30
Onsite Hours :04:30
Name of the Project :N. Gate - Old Atlanta Road
Project Location :Cumming
Weather :cloudy
Departure Time :02/14/2024 13:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
02/14/2024 1 17 101.7 24469 103.9 18.7 97.9 95 D6938 Pass
Location : Lot #25, Elv/Depth :2.5 feet below finished grade
Comment : Gauge Serial No. :85759
02/14/2024 2 20.7 103.3 24469 103.9 18.7 99.4 90 D6938 Pass
Location : Roadway in the front of Lot #25., Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :85759
02/14/2024 3 20.5 107.2 24468 111.3 17.5 96.3 95 D6938 Pass
Location : Lot #32, Elv/Depth :4 feet below finished grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, February 14, 2024
Reviewer Name / DateKenneth Mosman, March 12, 2024