Skip to content

Density Test Report

Date :02/19/2024
Project No :2023C195
Client Company :Toll Bros. Inc.
Arrival Time :02/19/2024 8:30
Onsite Hours :03:30
Name of the Project :Kimbal Bridge Tract
Project Location :Alpharetta
Weather :sunny
Departure Time :02/19/2024 12:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
02/19/2024 1 18.8 100.8 24209 111.6 16.5 90.3 90 D6938 Pass
Location : adjacent to retaining wall 9 (location shown in pictures), Elv/Depth :4 feet below from top of retaining wall
Comment : Gauge Serial No. :85759
02/19/2024 2 19.2 100.8 24208 110.4 16.3 91.3 90 D6938 Pass
Location : in the front of retaining wall 9 (location shown in the picture), Elv/Depth :8 feet below from top of wall
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, February 19, 2024
Reviewer Name / DateKenneth Mosman, March 13, 2024