Skip to content

Density Test Report

Date :02/21/2024
Project No :2023C195
Client Company :Toll Bros. Inc.
Arrival Time :02/21/2024 7:00
Onsite Hours :08:30
Name of the Project :Kimbal Bridge Tract
Project Location :Alpharetta
Weather :sunny
Departure Time :02/21/2024 15:30
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
02/21/2024 1 14.4 106.5 24209 111.6 16.5 95.4 95 D6938 Pass
Location : Retaining wall 9 back fill, Elv/Depth :finished grade
Comment : Gauge Serial No. :85759
02/21/2024 2 14.7 121.6 24209 111.6 16.5 95.0 95 D6938 Fail
Location : Retaining wall 9 back fill., Elv/Depth :finished grade
Comment : Gauge Serial No. :85759
02/21/2024 3 14.7 109.4 24209 111.6 16.5 98.0 95 D6938 Pass
Location : Basement for Lot #9., Elv/Depth :finished grade
Comment : Gauge Serial No. :85759
02/21/2024 4 17.6 95.2 SC 94.6 21.9 100.6 100 D6938 Pass
Location : Roadway in front of Lot #19,, Elv/Depth :finished grade
Comment : Gauge Serial No. :85979
02/21/2024 5 16.6 100.4 SC 94.6 21.9 106.1 100 D6938 Pass
Location : Roadway in front of Lot #20., Elv/Depth :finished grade
Comment : Gauge Serial No. :85759
02/21/2024 6 17.4 97.2 SC 94.6 21.9 102.7 100 D6938 Pass
Location : Lot #21, Elv/Depth :finished grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, February 21, 2024
Reviewer Name / DateRamchandra Mogulla, June 18, 2024