Skip to content

Density Test Report

Date :02/27/2024
Project No :2023C195
Client Company :Toll Bros. Inc.
Arrival Time :02/27/2024 8:30
Onsite Hours :03:00
Name of the Project :Kimbal Bridge Tract
Project Location :Alpharetta
Weather :cloudy
Departure Time :02/27/2024 11:30
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
02/27/2024 1 17.6 100.5 SC 94.6 21.9 106.2 100 D6938 Pass
Location : Roadway between Lots #13 and #32, Elv/Depth :finished grade
Comment : Gauge Serial No. :85759
02/27/2024 2 16.9 96.5 SC 94.6 21.9 102.0 100 D6938 Pass
Location : Roadway between Lots #14 and #33, Elv/Depth :finished grade
Comment : Gauge Serial No. :85759
02/27/2024 3 19.5 99.8 SC 94.6 21.9 105.5 100 D6938 Pass
Location : Roadway between Lot #34 and retaining wall 9, Elv/Depth :finished grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, February 27, 2024
Reviewer Name / DateRamchandra Mogulla, June 18, 2024