Density Test Report

Date :03/13/2024
Project No :2023C141
Client Company :Toll Bros
Arrival Time :03/13/2024 9:00
Onsite Hours :04:00
Name of the Project :N. Gate - Old Atlanta Road
Project Location :Cumming
Weather :sunny
Departure Time :03/13/2024 13:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
03/13/2024 1 17.6 102.3 24469 103.9 18.7 98.5 95 D6938 Pass
Location : Lot #34, Elv/Depth :finished grade
Comment : Gauge Serial No. :85759
03/13/2024 2 20.2 105.2 24469 103.9 18.7 101.3 95 D6938 Pass
Location : Lot #34 basement , Elv/Depth :finished grade
Comment : Gauge Serial No. :85759
03/13/2024 3 16.6 103.8 24469 103.9 18.7 99.9 95 D6938 Pass
Location : Lot #33, Elv/Depth :finished grade
Comment : Gauge Serial No. :85759
03/13/2024 4 17.2 104.2 24469 103.9 18.7 100.3 90 D6938 Pass
Location : Lot #33 basement , Elv/Depth :finished grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, March 13, 2024
Reviewer Name / DateKenneth Mosman, March 28, 2024