Density Test Report

Date :03/14/2024
Project No :2023C141
Client Company :Toll Bros
Arrival Time :03/14/2024 13:00
Onsite Hours :02:00
Name of the Project :N. Gate - Old Atlanta Road
Project Location :Cumming
Weather :sunny
Departure Time :03/14/2024 15:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
03/14/2024 1 19.6 106.0 24468 111.3 17.5 95.2 95 D6938 Pass
Location : Lot #31, Elv/Depth :7 feet below finished grade
Comment : Gauge Serial No. :85759
03/14/2024 2 20.6 104.1 24469 103.9 18.7 100.2 90 D6938 Pass
Location : Lot #31, basement , Elv/Depth :finished grade
Comment : Gauge Serial No. :85759
03/14/2024 3 17.6 103.2 24469 103.9 18.7 99.3 90 D6938 Pass
Location : Lot #31, Elv/Depth :6 feet below finished grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, March 14, 2024
Reviewer Name / DateKenneth Mosman, March 28, 2024