- Home
- Density Test Report Report ID: 66363
- Edit Download Report
Density Test Report
Date :05/01/2024
Project No :2024C112
Client Company :SR Homes
Arrival Time :05/01/2024
Onsite Hours :
Name of the Project :Sterlington
Project Location :Canton
Weather :overcast
Departure Time :05/01/2024
ASEC Technician Name :Russell Hendrix
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
05/01/2024 | 1 | 13 | 94.0 | P-01 | 94.8 | 25.0 | 99.2 | 95 | D6938 | Pass |
Location : | 7a-12 to Lot #1 lateral, Elv/Depth :-2 feet from finished grade | |||||||||
Comment : | Gauge Serial No. :30942 | |||||||||
05/01/2024 | 2 | 13.2 | 94.5 | P-01 | 94.8 | 25.0 | 99.7 | 95 | D6938 | Pass |
Location : | 7a-12 to Lot #1 lateral, Elv/Depth :-1 foot from finished grade | |||||||||
Comment : | future Roadway section will also be proof-rolled at a later date. | Gauge Serial No. :30942 |
Technician Signature / DateRussell Hendrix, May 1, 2024
Reviewer Name / DateKenneth Mosman, May 24, 2024