- Home
- Density Test Report Report ID: 66439
- This project is inactive from admin. Download Report
Density Test Report
Date :05/07/2024
Project No :2021C002
Client Company :CW Matthews
Arrival Time :05/07/2024 7:30
Onsite Hours :9:00
Name of the Project :Runway 9L End Around Taxiway
Project Location :HJAIA
Weather :cloudy
Departure Time :05/07/2024 16:30
ASEC Technician Name :Aminullah Azimi
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 05/07/2024 | 1 | 8.5 | 119.5 | 4 | 122.7 | 10.6 | 97.4 | 95 | D6938 | Pass |
| Location : | Bend 30, at STA 7021+32.82, Elv/Depth :1.5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
Technician Signature / DateAminullah Azimi, May 7, 2024
Reviewer Name / DateKenneth Mosman, July 10, 2024