- Home
- Density Test Report Report ID: 68867
- This project is inactive from admin. Download Report
Density Test Report
Date :08/16/2024
Project No :2024C116
Client Company :Peeples Owner, LLC
Arrival Time :08/16/2024 08:30
Onsite Hours :08:30
Name of the Project :Peeples Valley Rd, Overlook at Pettit
Project Location :Cartersville
Weather :Sunny
Departure Time :08/16/2024 17:00
ASEC Technician Name :Fawad Shagiwal
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 08/16/2024 | 1 | 18.5 | 103.8 | P-01 | 108.9 | 17.9 | 95.3 | 95 | D6938 | Pass |
| Location : | Backfilling area of segmental retaining wall (SRW), Elv/Depth :8 inches below finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
| 08/16/2024 | 2 | 17.7 | 104.6 | P-01 | 108.9 | 17.9 | 96.1 | 95 | D6938 | Pass |
| Location : | Backfilling area of segmental retaining wall (SRW), Elv/Depth :8 inches below finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
| 08/16/2024 | 3 | 17.9 | 104.7 | P-01 | 108.9 | 17.9 | 96.1 | 95 | D6938 | Pass |
| Location : | Backfilling area of segmental retaining wall (SRW), Elv/Depth :8 inches below finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
| 08/16/2024 | 4 | 17.8 | 104.6 | P-01 | 108.9 | 17.9 | 96.1 | 95 | D6938 | Pass |
| Location : | Backfilling area of segmental retaining wall (SRW), Elv/Depth :8 inches below finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
Technician Signature / DateFawad Shagiwal, August 16, 2024
Reviewer Name / DateKenneth Mosman, October 21, 2024