- Home
- Density Test Report Report ID: 70706
- This project is inactive from admin. Download Report
Density Test Report
Date :09/23/2024
Project No :2024C168
Client Company :CCG
Arrival Time :09/23/2024 8:00
Onsite Hours :10:30
Name of the Project :Reserve @ Gum Springs
Project Location :Jefferson
Weather :cloudy
Departure Time :09/23/2024 18:30
ASEC Technician Name :Aminullah Azimi
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 09/23/2024 | 118 | 22.3 | 86.3 | 26082 | 94.1 | 24.3 | 91.7 | 95 | D2937 | Fail |
| Location : | Storm water trench, 9 feet NW from MHA2.5, Elv/Depth :3.5 feet below finished grade | |||||||||
| Comment : | ||||||||||
| 09/23/2024 | 119 | 26.7 | 89.7 | 26082 | 94.1 | 24.3 | 95.3 | 95 | D2937 | Pass |
| Location : | Storm water trench, 10 feet SE from MHA2, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | ||||||||||
| 09/23/2024 | 120 | 26.5 | 91.1 | 26082 | 94.1 | 24.3 | 96.8 | 95 | D2937 | Pass |
| Location : | Serwer trench, 10 feet SE from MHSK1, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | ||||||||||
| 09/23/2024 | 121 | 21.1 | 97.9 | 26081 | 102.9 | 20.0 | 95.1 | 95 | D2937 | Pass |
| Location : | Sewer trench, 10 feet NW from MHSSK1, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | ||||||||||
| 09/23/2024 | 122 | 26.3 | 91.3 | 26082 | 94.1 | 24.3 | 97.0 | 95 | D2937 | Pass |
| Location : | Service line for Lot #188, Elv/Depth :2.5 feet below finished grade | |||||||||
| Comment : | ||||||||||
| 09/23/2024 | 123 | 20.3 | 98.3 | 26081 | 102.9 | 20.0 | 95.5 | 95 | D2937 | Pass |
| Location : | Sewer trench, 10 feet NE from MHSK2, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | ||||||||||
| 09/23/2024 | 124 | 21.6 | 98.5 | 26081 | 102.9 | 20.0 | 95.7 | 95 | D2937 | Pass |
| Location : | Service line for Lot #1, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | ||||||||||
| 09/23/2024 | 125 | 23.6 | 89.9 | 26082 | 94.1 | 24.3 | 95.5 | 95 | D2937 | Pass |
| Location : | Sewer trench, 9 feet SE from MHSK2, Elv/Depth :3 feet below finished grade | |||||||||
| Comment : | ||||||||||
| 09/23/2024 | 126 | 22.2 | 100.5 | 26081 | 102.9 | 20.0 | 97.7 | 95 | D2937 | Pass |
| Location : | Storm water trench, 10 feet NW from MHB13., Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | ||||||||||
| 09/23/2024 | 127 | 25.0 | 90.9 | 26082 | 94.1 | 24.3 | 96.6 | 95 | D2937 | Pass |
| Location : | Storm trench, 12 feet SE from MHB14, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | ||||||||||
Technician Signature / DateAminullah Azimi, September 23, 2024
Reviewer Name / DateKenneth Mosman, October 20, 2024