Skip to content

Density Test Report

Date :10/12/2024
Project No :2023C201
Client Company :Artisan Built Communities
Arrival Time :10/12/2024 08:00
Onsite Hours :06:00
Name of the Project :Jasons Walk - Era Drive
Project Location :Era Drive, Cumming, GA
Weather :Sunny
Departure Time :10/12/2024 14:00
ASEC Technician Name :Fawad Shagiwal

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
10/12/2024 1 18.5 122.3 24504 101.6 20.6 101.6 95 D6938 Pass
Location : Lot #07, Elv/Depth :at finished grade
Comment : Gauge Serial No. :29588
10/12/2024 2 20.5 99.7 24504 101.6 20.6 98.1 95 D6938 Pass
Location : Lot #07, Elv/Depth :at finished grade
Comment : Gauge Serial No. :29588
10/12/2024 3 22.8 97.9 24504 101.6 20.6 96.4 95 D6938 Pass
Location : Lot #12, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :29588
10/12/2024 4 22.9 99.3 24504 101.6 20.6 97.7 95 D6938 Pass
Location : Lot #12, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :29588
10/12/2024 5 23.2 98.8 24504 101.6 20.6 97.2 95 D6938 Pass
Location : Lot #12, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :29588
10/12/2024 6 20.8 100.1 24504 101.6 20.6 98.5 95 D6938 Pass
Location : Lot #06, Elv/Depth :4 feet below finished grade
Comment : Gauge Serial No. :29588
Technician Signature / DateFawad Shagiwal, October 12, 2024
Reviewer Name / DateKenneth Mosman, February 01, 2025