Skip to content

Density Test Report

Date :09/24/2024
Project No :2024C237
Client Company :SR Homes
Arrival Time :09/24/2024 13:00
Onsite Hours :05:30
Name of the Project :Stonewood PH 4, Stone Road
Project Location :Watkinsville
Weather :sunny
Departure Time :09/24/2024 18:30
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
09/24/2024 1 18.1 99.4 S-01 101.2 18.6 98.2 98 D6938 Pass
Location : Road (location shown in the picture), Elv/Depth :at finished grade
Comment : Gauge Serial No. :85759
09/24/2024 2 17.5 99.5 S-01 101.2 18.6 98.3 98 D6938 Pass
Location : Road (location shown in picture), Elv/Depth :finished grade
Comment : Gauge Serial No. :85759
09/24/2024 3 19.2 100.5 S-01 101.2 18.6 99.3 98 D6938 Pass
Location : Road ( location shown in picture), Elv/Depth :finished grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, September 24, 2024
Reviewer Name / DateKenneth Mosman, January 12, 2025