- Home
- Density Test Report Report ID: 71939
- This project is inactive from admin. Download Report
Density Test Report
Date :10/07/2024
Project No :2024C237
Client Company :SR Homes
Arrival Time :10/07/2024 7:30
Onsite Hours :05:00
Name of the Project :Stonewood PH 4, Stone Road
Project Location :Watkinsville
Weather :sunny
Departure Time :10/07/2024 12:30
ASEC Technician Name :Aminullah Azimi
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 10/07/2024 | 1 | 23.1 | 98.9 | S-01 | 101.2 | 18.6 | 97.7 | 95 | D6938 | Pass |
| Location : | Roadway (location shown in the picture) , Elv/Depth :8 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :85759 | |||||||||
| 10/07/2024 | 2 | 24.4 | 99.8 | S-01 | 101.2 | 18.6 | 98.6 | 95 | D6938 | Pass |
| Location : | Roadway (location shown in the picture) , Elv/Depth :7 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :85759 | |||||||||
Technician Signature / DateAminullah Azimi, October 7, 2024
Reviewer Name / DateKenneth Mosman, January 12, 2025