Skip to content

Density Test Report

Date :10/17/2024
Project No :2024C237
Client Company :SR Homes
Arrival Time :10/17/2024 8:30
Onsite Hours :03:30
Name of the Project :Stonewood PH 4, Stone Road
Project Location :Watkinsville
Weather :sunny
Departure Time :10/17/2024 12:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
10/17/2024 1 19.2 103.2 S-02 104.0 19.1 99.2 95 D6938 Pass
Location : roadway circle (location is shown in picture) , Elv/Depth :0.5 feet below finished grade
Comment : Gauge Serial No. :85759
10/17/2024 2 19.7 103.9 S-02 104.0 19.1 99.9 95 D6938 Pass
Location : roadway circle (location shown in pictures), Elv/Depth :1 foot below finished grade
Comment : Gauge Serial No. :85759
10/17/2024 3 20.3 102.8 S-02 104.0 19.1 98.8 95 D6938 Pass
Location : roadway circle (location shown in the picture) , Elv/Depth :1 foot below finished grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, October 17, 2024
Reviewer Name / DateKenneth Mosman, January 12, 2025