Skip to content

Density Test Report

Date :10/18/2024
Project No :2024C237
Client Company :SR Homes
Arrival Time :10/18/2024 8:30
Onsite Hours :03:30
Name of the Project :Stonewood PH 4, Stone Road
Project Location :Watkinsville
Weather :sunny
Departure Time :10/18/2024 12:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
10/18/2024 1 20.3 103.0 S-02 104.0 19.1 99.0 98 D6938 Pass
Location : roadway circle (location shown in the picture), Elv/Depth :finished grade
Comment : Gauge Serial No. :85759
10/18/2024 2 20.9 102.6 S-02 104.0 19.1 98.7 98 D6938 Pass
Location : roadway circle (location shown in the picture), Elv/Depth :finished grade
Comment : Gauge Serial No. :85759
10/18/2024 3 19.9 102.2 S-02 104.0 19.1 98.3 98 D6938 Pass
Location : roadway circle (location shown in the picture), Elv/Depth :finished grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, October 18, 2024
Reviewer Name / DateKenneth Mosman, January 12, 2025