- Home
- Density Test Report Report ID: 72343
- This project is inactive from admin. Download Report
Density Test Report
Date :10/26/2024
Project No :2024C168
Client Company :CCG
Arrival Time :10/26/2024 8:30
Onsite Hours :05:30
Name of the Project :Reserve @ Gum Springs
Project Location :Jefferson
Weather :sunny
Departure Time :10/26/2024 14:00
ASEC Technician Name :Aminullah Azimi
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 10/26/2024 | 230 | 19.1 | 92.8 | 26082 | 94.1 | 24.3 | 98.6 | 95 | D6938 | Pass |
| Location : | Storm water trench, 15 feet NE from MHC12, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | Moisture content was lower than specified moisture limit. | Gauge Serial No. :85759 | ||||||||
| 10/26/2024 | 231 | 25.4 | 90.4 | 26082 | 94.1 | 24.3 | 96.1 | 95 | D6938 | Pass |
| Location : | Storm water trench, 12 feet NE from MHC13, Elv/Depth :1.5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :85759 | |||||||||
| 10/26/2024 | 232 | 22.5 | 98.4 | 26081 | 102.9 | 20.0 | 95.6 | 95 | D6938 | Pass |
| Location : | Storm water trench, 48 feet SW from MHC13, Elv/Depth :2.5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :85759 | |||||||||
Technician Signature / DateAminullah Azimi, October 26, 2024
Reviewer Name / DateKenneth Mosman, November 05, 2024