- Home
- Density Test Report Report ID: 72494
- This project is inactive from admin. Download Report
Density Test Report
Date :10/30/2024
Project No :2024C237
Client Company :SR Homes
Arrival Time :10/30/2024 14:30
Onsite Hours :03:00
Name of the Project :Stonewood PH 4, Stone Road
Project Location :Watkinsville
Weather :sunny
Departure Time :10/30/2024 17:30
ASEC Technician Name :Aminullah Azimi
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 10/30/2024 | 1 | 21.5 | 123.9 | S-02 | 104.0 | 19.1 | 98.1 | 98 | D6938 | Pass |
| Location : | Roadway location is shown in the picture, Elv/Depth :finished grade | |||||||||
| Comment : | Gauge Serial No. :85759 | |||||||||
| 10/30/2024 | 2 | 23.3 | 102.9 | S-02 | 104.0 | 19.1 | 98.9 | 98 | D6938 | Pass |
| Location : | roadway location shown in the picture , Elv/Depth :finished grade | |||||||||
| Comment : | Gauge Serial No. :85759 | |||||||||
| 10/30/2024 | 3 | 28.3 | 93.1 | S-02 | 104.0 | 19.1 | 89.5 | 98 | D6938 | Fail |
| Location : | Roadway location is shown in the picture , Elv/Depth :finished grade | |||||||||
| Comment : | In place moisture contents much higher than optimum. Recommend scarify and aerate soils prior to recompaction. | Gauge Serial No. :85759 | ||||||||
Technician Signature / DateAminullah Azimi, October 30, 2024