Density Test Report

Date :10/30/2024
Project No :2024C237
Client Company :SR Homes
Arrival Time :10/30/2024 14:30
Onsite Hours :03:00
Name of the Project :Stonewood PH 4, Stone Road
Project Location :Watkinsville
Weather :sunny
Departure Time :10/30/2024 17:30
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
10/30/2024 1 21.5 123.9 S-02 104.0 19.1 98.1 98 D6938 Pass
Location : Roadway location is shown in the picture, Elv/Depth :finished grade
Comment : Gauge Serial No. :85759
10/30/2024 2 23.3 102.9 S-02 104.0 19.1 98.9 98 D6938 Pass
Location : roadway location shown in the picture , Elv/Depth :finished grade
Comment : Gauge Serial No. :85759
10/30/2024 3 28.3 93.1 S-02 104.0 19.1 89.5 98 D6938 Fail
Location : Roadway location is shown in the picture , Elv/Depth :finished grade
Comment : In place moisture contents much higher than optimum. Recommend scarify and aerate soils prior to recompaction. Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, October 30, 2024