Density Test Report
Date :11/13/2024
Project No :2024C237
Client Company :SR Homes
Arrival Time :11/13/2024 8:00
Onsite Hours :04:00
Name of the Project :Stonewood PH 4, Stone Road
Project Location :Watkinsville
Weather :sunny
Departure Time :11/13/2024 12:00
ASEC Technician Name :Aminullah Azimi
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 11/13/2024 | 1 | 22.1 | 99.2 | S-02 | 104.0 | 19.1 | 95.4 | 95 | D6938 | Pass |
| Location : | Stormwater trench, 13 feet SW from MH2, Elv/Depth :1.5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :85759 | |||||||||
| 11/13/2024 | 2 | 23 | 121.9 | S-02 | 104.0 | 19.1 | 95.3 | 95 | D6938 | Pass |
| Location : | Stormwater trench, 25 feet NE from MHA1, Elv/Depth :1.5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :85759 | |||||||||
| 11/13/2024 | 3 | 22.4 | 99.4 | S-02 | 104.0 | 19.1 | 95.6 | 95 | D6938 | Pass |
| Location : | Stormwater trench, between HWA0 and MHA1, Elv/Depth :finished grade | |||||||||
| Comment : | Gauge Serial No. :85759 | |||||||||
Technician Signature / DateAminullah Azimi, November 13, 2024
Reviewer Name / DateKenneth Mosman, January 12, 2025