Skip to content

Density Test Report

Date :11/18/2024
Project No :2024C202
Client Company :CCG
Arrival Time :11/18/2024 07:30
Onsite Hours :
Name of the Project :Old Griffin Rd - Hawthorne Reserve
Project Location :Dallas
Weather :Sunny
Departure Time :
ASEC Technician Name :Solomon Cherie

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
11/18/2024 101 30.6 91.1 S-02 97.2 24.9 93.7 95 D6938 Fail
Location : Lot#74, Elv/Depth :-1.5
Comment : The second test still shows that the dirt is still wet, and the compaction failed, that is below 95%. I told to the super to scarify for an hour roll it and do backfill. The super accepted the suggestion. Gauge Serial No. :30942
Technician Signature / DateSolomon Cherie, November 18, 2024
Reviewer Name / DateKenneth Mosman, January 09, 2025