- Home
- Concrete Test Report Report ID: 73578
- Edit Download Report
Concrete Test Report
Date :11/26/2024
Project No :2024C189
Client Company :WSP
Arrival Time :11/26/2024 00:30
Onsite Hours :07:00
Name of the Project :Protovision PH II
Project Location :Lithia Springs
Weather :Cloudy
Departure Time :11/26/2024 07:30
ASEC Technician Name :Solomon Cherie
Concrete Placement Information
Location(S):
N/A
Testing:
1 Set of concrete specimens (5 per set) were cast during the cast-in-place concrete pour at the above referenced location, in accordance with ASTM C31. The specimen will remain on site for the initial 24-48 hrs curing.
Compliance:
Field placement of concrete appeared to be in accordance with the project specifications (i.e., slump, temperature, etc) (refer to remarks below)
Deviations and/or noncompliances were noted during the field placement (refer to remarks below)
Specimen
Pick Up: 1 Sets of concrete specimens/ 5 specimen per set were picked up & transported to AS Engineering and Consulting LLC (ASEC) for curing and testing in accordance with ASTM C39, C670/1231
Pick Up: 1 Sets of concrete specimens/ 5 specimen per set were picked up & transported to AS Engineering and Consulting LLC (ASEC) for curing and testing in accordance with ASTM C39, C670/1231
Field Curing:
Specimen were stored for the initial 24 hours.
Near the poured structure
In an insulated curing box
Other
Remarks:
In this test, the mix is 3000psi and the results were:
Air=1.2%
Slump=5.5"
Temperature=65°F
Unit weight=145.2psi
Technician Signature / DateSolomon Cherie, November 26, 2024
Reviewer Name / DateKenneth Mosman, January 12, 2025
