- Home
- Density Test Report Report ID: 73604
- Edit Download Report
Density Test Report
Date :11/26/2024
Project No :2024C202
Client Company :CCG
Arrival Time :11/26/2024 10:45
Onsite Hours :
Name of the Project :Old Griffin Rd - Hawthorne Reserve
Project Location :Dallas
Weather :Cloudy
Departure Time :11/26/2024
ASEC Technician Name :Solomon Cherie
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 11/26/2024 | 1 | 28.6 | 87.2 | S-02 | 97.2 | 24.9 | 89.7 | 95 | D6938 | Fail |
| Location : | Lot #73, Elv/Depth :5 feet below finished grade | |||||||||
| Comment : | In place moisture contents more than 3 percent over optimum. Scarifying, aerating and recompaction required. | Gauge Serial No. :30942 | ||||||||
| 11/26/2024 | 2 | 31.7 | 108.8 | S-02 | 97.2 | 24.9 | 85.0 | 95 | D6938 | Fail |
| Location : | Access road, Elv/Depth :3 feet below finished grade | |||||||||
| Comment : | In place moisture contents more than 3 percent over optimum. Scarifying, aerating and recompaction required. | Gauge Serial No. :30942 | ||||||||
Technician Signature / DateSolomon Cherie, November 26, 2024
Reviewer Name / DateKenneth Mosman, January 10, 2025