- Home
- Density Test Report Report ID: 74176
- This project is inactive from admin. Download Report
Density Test Report
Date :12/06/2024
Project No :2024C168
Client Company :CCG
Arrival Time :12/06/2024 8:00
Onsite Hours :9:00
Name of the Project :Reserve @ Gum Springs
Project Location :Jefferson
Weather :cloudy
Departure Time :12/06/2024 17:00
ASEC Technician Name :Aminullah Azimi
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 12/06/2024 | 354 | 27.5 | 92.6 | 26082 | 94.1 | 24.3 | 98.4 | 95 | D2937 | Pass |
| Location : | water line, in front of Lot #188, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | ||||||||||
| 12/06/2024 | 355 | 20.7 | 100.3 | 26081 | 102.9 | 20.0 | 97.5 | 95 | D2937 | Pass |
| Location : | water line in front of Lot #190, Elv/Depth :1.5 feet below finished grade | |||||||||
| Comment : | ||||||||||
| 12/06/2024 | 356 | 22.7 | 97.3 | 26083 | 102.0 | 22.1 | 95.4 | 95 | D2937 | Pass |
| Location : | water line in front of Lot #192, Elv/Depth :1.5 feet below finished grade | |||||||||
| Comment : | ||||||||||
| 12/06/2024 | 357 | 22.1 | 98.9 | 26081 | 102.9 | 20.0 | 96.1 | 95 | D2937 | Pass |
| Location : | water line in front of Lot #178, Elv/Depth :finished grade | |||||||||
| Comment : | ||||||||||
| 12/06/2024 | 358 | 19.3 | 100.7 | 26081 | 102.9 | 20.0 | 97.9 | 95 | D2937 | Pass |
| Location : | water line in front of Lot #189, Elv/Depth :finished grade | |||||||||
| Comment : | ||||||||||
| 12/06/2024 | 359 | 22.4 | 98.1 | 26081 | 102.9 | 20.0 | 95.3 | 95 | D2937 | Pass |
| Location : | water line in front of Lot #191, Elv/Depth :finished grade | |||||||||
| Comment : | ||||||||||
| 12/06/2024 | 360 | 17.2 | 95.6 | 26086 | 99.8 | 19.7 | 95.8 | 95 | D6938 | Pass |
| Location : | retaining wall, at Station 43+00, Elv/Depth :7 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :85759 | |||||||||
Technician Signature / DateAminullah Azimi, December 6, 2024
Reviewer Name / DateKenneth Mosman, January 11, 2025