Density Test Report

Date :12/17/2024
Project No :2024C202
Client Company :CCG
Arrival Time :12/17/2024 07:30
Onsite Hours :
Name of the Project :Old Griffin Rd - Hawthorne Reserve
Project Location :Dallas
Weather :Cloudy
Departure Time :
ASEC Technician Name :Solomon Cherie

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
12/17/2024 1 27.5 92.0 S-02 97.2 24.9 94.7 95 D6938 Fail
Location : Lot #114, Elv/Depth :2 feet below finished grade
Comment : This test deemed satisfactory following a short proof-roll that found the area stable. Gauge Serial No. :30942
12/17/2024 2 26.1 95.7 S-02 97.2 24.9 98.5 95 D6938 Pass
Location : Lot #115, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :30942
12/17/2024 3 27.4 92.5 S-02 97.2 24.9 95.2 95 D6938 Pass
Location : Lot #114, Elv/Depth :at finished grade
Comment : Gauge Serial No. :30942
Technician Signature / DateSolomon Cherie, December 17, 2024
Reviewer Name / DateKenneth Mosman, January 10, 2025