- Home
- Density Test Report Report ID: 74615
- Edit Download Report
Density Test Report
Date :12/19/2024
Project No :2024C202
Client Company :CCG
Arrival Time :12/19/2024 07:30
Onsite Hours :
Name of the Project :Old Griffin Rd - Hawthorne Reserve
Project Location :Dallas
Weather :Cloudy
Departure Time :
ASEC Technician Name :Solomon Cherie
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 12/19/2024 | 1 | 27.2 | 117.7 | S-02 | 97.2 | 24.9 | 95.2 | 95 | D6938 | Pass |
| Location : | Lot #73, Elv/Depth :at finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 12/19/2024 | 2 | 21.8 | 95.9 | S-02 | 97.2 | 24.9 | 98.7 | 95 | D6938 | Pass |
| Location : | Sewer line b/n Manhole A12 and A13, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 12/19/2024 | 3 | 24.2 | 95.1 | S-02 | 97.2 | 24.9 | 97.8 | 95 | D6938 | Pass |
| Location : | Sewer line b/n Manhole A12 & A13, Elv/Depth :at finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
Technician Signature / DateSolomon Cherie, December 19, 2024
Reviewer Name / DateKenneth Mosman, January 10, 2025