- Home
- Density Test Report Report ID: 75868
- This project is inactive from admin. Download Report
Density Test Report
Date :01/04/2025
Project No :2024C168
Client Company :CCG
Arrival Time :01/04/2025 8:15
Onsite Hours :07:15
Name of the Project :Reserve @ Gum Springs
Project Location :Jefferson
Weather :sunny
Departure Time :01/04/2025 15:30
ASEC Technician Name :Aminullah Azimi
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 01/04/2025 | 421 | 23.7 | 90.5 | 26082 | 94.1 | 24.3 | 96.2 | 95 | D2937 | Pass |
| Location : | SSFM in front of Lot #135, Elv/Depth :1.5 feet below finished grade | |||||||||
| Comment : | ||||||||||
| 01/04/2025 | 422 | 24.0 | 90.1 | 26082 | 94.1 | 24.3 | 95.7 | 95 | D2937 | Pass |
| Location : | SSFM in front of Lot #134, Elv/Depth :1.5 feet below finished grade | |||||||||
| Comment : | ||||||||||
| 01/04/2025 | 423 | 24.5 | 91.3 | 26082 | 94.1 | 24.3 | 97.0 | 95 | D2937 | Pass |
| Location : | SSFM in front of Lot #133, Elv/Depth :finished grade | |||||||||
| Comment : | ||||||||||
Technician Signature / DateAminullah Azimi, January 4, 2025
Reviewer Name / DateKenneth Mosman, January 17, 2025