- Home
- Density Test Report Report ID: 78979
- This project is inactive from admin. Download Report
Density Test Report
Date :02/25/2025
Project No :2024C237
Client Company :SR Homes
Arrival Time :02/25/2025 11:30
Onsite Hours :06:30
Name of the Project :Stonewood PH 4, Stone Road
Project Location :Watkinsville
Weather :sunny
Departure Time :02/25/2025 18:00
ASEC Technician Name :Aminullah Azimi
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 02/25/2025 | 1 | 22.2 | 99.9 | S-02 | 104.0 | 19.1 | 96.1 | 95 | D6938 | Pass |
| Location : | outlet control structure at detention pond , Elv/Depth :3 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :85759 | |||||||||
| 02/25/2025 | 2 | 22.1 | 100.8 | S-02 | 104.0 | 19.1 | 96.9 | 95 | D6938 | Pass |
| Location : | outlet control structure at detention pond , Elv/Depth :1.5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :85759 | |||||||||
| 02/25/2025 | 3 | 22.5 | 99.0 | S-02 | 104.0 | 19.1 | 95.2 | 95 | D6938 | Pass |
| Location : | outlet control structure at detention pond , Elv/Depth :at finished grade | |||||||||
| Comment : | Gauge Serial No. :85759 | |||||||||
Technician Signature / DateAminullah Azimi, February 25, 2025
Reviewer Name / DateKenneth Mosman, April 29, 2025