Skip to content

Density Test Report

Date :03/20/2025
Project No :2024C213
Client Company :WDG
Arrival Time :03/20/2025 10:00
Onsite Hours :06:30
Name of the Project :Covington Town Center PH II
Project Location :Covington, GA
Weather :Clear
Departure Time :03/20/2025 16:30
ASEC Technician Name :Clyde Smith

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
03/20/2025 1 20.6 101.2 ASECP001 106.0 18.2 95.5 95 D6938 Pass
Location : Bldg. pad 18' west of SE corner, Elv/Depth :817.00
Comment : Gauge Serial No. :29588
03/20/2025 2 21.3 102.3 ASECP001 106.0 18.2 96.5 95 D6938 Pass
Location : Bldg pad 30' west, 40' N of SE corner, Elv/Depth :817.00
Comment : Gauge Serial No. :29588
03/20/2025 3 19.9 103.8 ASECP001 106.0 18.2 97.9 95 D6938 Pass
Location : Bldg.pad 70' west, 40'N of SE corner, Elv/Depth :818.5
Comment : Gauge Serial No. :29588
03/20/2025 4 18.2 102.3 ASECP001 106.0 18.2 96.5 95 D6938 Pass
Location : Bldg.pad 20'west, 25'N of SE.corner, Elv/Depth :819.5
Comment : Gauge Serial No. :29588
03/20/2025 5 18.3 103.0 ASECP001 106.0 18.2 97.2 95 D6938 Pass
Location : Bldg.pad 70'N, 35'west of SE. corner, Elv/Depth :819.00
Comment : Gauge Serial No. :29855
03/20/2025 6 20.2 104.1 ASECP001 106.0 18.2 98.2 95 D6938 Pass
Location : Bldg.pad 78'N, 46'west of SE.corner, Elv/Depth :820.00
Comment : Gauge Serial No. :29855
03/20/2025 7 20.9 104.7 ASECP001 106.0 18.2 98.8 95 D6938 Pass
Location : Bldg.pad 65' west, 60'N of SE.corner, Elv/Depth :820.5
Comment : Gauge Serial No. :29855
Technician Signature / DateClyde Smith, March 20, 2025
Reviewer Name / DateKenneth Mosman, April 29, 2025