Density Test Report

Date :03/25/2025
Project No :2024C213
Client Company :WDG
Arrival Time :03/25/2025 14:00
Onsite Hours :02:30
Name of the Project :Covington Town Center PH II
Project Location :Covington, GA
Weather :
Departure Time :03/25/2025 16:30
ASEC Technician Name :Clyde Smith

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
03/25/2025 1 16.8 105.1 ASECP001 106.0 18.2 99.2 98 D6938 Pass
Location : NE building. corner, Elv/Depth :822.00
Comment : Gauge Serial No. :29855
03/25/2025 2 17.0 106.1 ASECP001 106.0 18.2 100.1 98 D6938 Pass
Location : SE corner of building, Elv/Depth :822.00
Comment : Gauge Serial No. :29588
03/25/2025 3 16.5 104.3 ASECP001 106.0 18.2 98.4 98 D6938 Pass
Location : SW corner of building, Elv/Depth :822.0
Comment : Gauge Serial No. :29588
03/25/2025 4 17.4 104.3 ASECP001 106.0 18.2 98.4 98 D6938 Pass
Location : NW corner of building, Elv/Depth :822.0
Comment : Gauge Serial No. :29588
Technician Signature / DateClyde Smith, March 25, 2025
Reviewer Name / DateKenneth Mosman, April 30, 2025