- Home
- Density Test Report Report ID: 79203
- Edit Download Report
Density Test Report
Date :03/28/2025
Project No :2024C202
Client Company :CCG
Arrival Time :03/28/2025 07:30
Onsite Hours :
Name of the Project :Old Griffin Rd - Hawthorne Reserve
Project Location :Dallas
Weather :
Departure Time :
ASEC Technician Name :Solomon Cherie
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 03/28/2025 | 1 | 27.5 | 95.6 | S-02 | 97.2 | 24.9 | 98.4 | 95 | D6938 | Pass |
| Location : | Roadway, Elv/Depth :at finished subgrade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 03/28/2025 | 2 | 33.3 | 85.3 | S-02 | 97.2 | 24.9 | 87.8 | 95 | D6938 | Fail |
| Location : | Lot #26, Elv/Depth :1.5 feet below finished sugrade | |||||||||
| Comment : | In-situ moisture contents well above optimum. Recommended scarify, aerate and recompact to the contractor. | Gauge Serial No. :30942 | ||||||||
Technician Signature / DateSolomon Cherie, March 28, 2025
Reviewer Name / DateKenneth Mosman, May 01, 2025