Density Test Report
Date :04/09/2025
Project No :2025C150
Client Company :Davidson Homes
Arrival Time :04/09/2025 08:00
Onsite Hours :9:00
Name of the Project :Riverwood Retaining Wall
Project Location :Dallas
Weather :sunny
Departure Time :04/09/2025 17:00
ASEC Technician Name :Vamsi Polisetty
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 04/09/2025 | 1 | 28.2 | 109.6 | 2025-009 SP | 89.2 | 25.2 | 95.9 | 95 | D6938 | Pass |
| Location : | Lot #229 (next to Lot #228), Elv/Depth :first lift | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
| 04/09/2025 | 2 | 29.5 | 86.6 | 2025-009 SP | 89.2 | 25.2 | 97.1 | 95 | D6938 | Pass |
| Location : | Lot #228 (random station next to Lot #227), Elv/Depth :first lift | |||||||||
| Comment : | In-situ moisture contents well above optimum moisture contents. | Gauge Serial No. :29588 | ||||||||
| 04/09/2025 | 3 | 28.3 | 90.3 | 2025-009 SP | 89.2 | 25.2 | 101.2 | 95 | D6938 | Pass |
| Location : | Lot #228 (random station next to Lot #227), Elv/Depth :first lift | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
| 04/09/2025 | 4 | 24.3 | 112.4 | 2025-009 SP | 89.2 | 25.2 | 101.3 | 95 | D6938 | Pass |
| Location : | Lot #227 (random station next to Lot #226), Elv/Depth :first lift | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
| 04/09/2025 | 5 | 26.8 | 92.0 | 2025-009 SP | 89.2 | 25.2 | 103.1 | 95 | D6938 | Pass |
| Location : | Lot #227 (random station next to Lot #226), Elv/Depth :first lift | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
| 04/09/2025 | 6 | 31.7 | 88.2 | 2025-009 SP | 89.2 | 25.2 | 98.9 | 95 | D6938 | Pass |
| Location : | Lot #226 (random station next to Lot #225), Elv/Depth :first lift | |||||||||
| Comment : | In-situ moisture contents well above optimum moisture. | Gauge Serial No. :29588 | ||||||||
| 04/09/2025 | 7 | 24.9 | 92.6 | 2025-009 SP | 89.2 | 25.2 | 103.8 | 95 | D6938 | Pass |
| Location : | Lot #225 (random station in Lot #225), Elv/Depth :first lift | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
Technician Signature / DateVamsi Polisetty, April 9, 2025