Skip to content

Density Test Report

Date :04/09/2025
Project No :2025C150
Client Company :Davidson Homes
Arrival Time :04/09/2025 08:00
Onsite Hours :9:00
Name of the Project :Riverwood Retaining Wall
Project Location :Dallas
Weather :sunny
Departure Time :04/09/2025 17:00
ASEC Technician Name :Vamsi Polisetty

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
04/09/2025 1 22.6 98.3 2025-015 SP 102.8 18.1 95.6 95 D6938 Pass
Location : Lot #229 (random station next to Lot #228), Elv/Depth :second lift
Comment : Gauge Serial No. :29588
04/09/2025 2 24.5 90.2 2025-009 SP 89.2 25.2 101.1 95 D6938 Pass
Location : Lot #228 (random station next to Lot #227), Elv/Depth :second lift
Comment : Gauge Serial No. :29588
04/09/2025 3 27.1 113.3 2025-009 SP 89.2 25.2 99.9 95 D6938 Pass
Location : Lot #227 (random station next to Lot #226), Elv/Depth :second lift
Comment : Gauge Serial No. :29588
04/09/2025 4 28.9 89.4 2025-009 SP 89.2 25.2 100.2 95 D6938 Pass
Location : Lot #227 (random station next to Lot #226), Elv/Depth :second lift
Comment : Gauge Serial No. :29588
04/09/2025 5 27.3 111.9 2025-009 SP 89.2 25.2 98.5 95 D6938 Pass
Location : Lot #226 (random station next to Lot #225), Elv/Depth :second lift
Comment : Gauge Serial No. :29588
04/09/2025 6 29.0 114.2 2025-009 SP 89.2 25.2 99.2 95 D6938 Pass
Location : Lot #226 (random station next to Lot #225), Elv/Depth :second lift
Comment : In-situ moisture contents are nearing high limits for optimum moisture (makes achieving compaction more difficult). Gauge Serial No. :29588
04/09/2025 7 24.6 91.9 2025-019 SP 95.8 21.5 95.9 95 D6938 Pass
Location : Lot #225 (random station near Lot #225), Elv/Depth :second lift
Comment : Gauge Serial No. :29588
Technician Signature / DateVamsi Polisetty, April 9, 2025
Reviewer Name / DateKenneth Mosman, May 02, 2025