Skip to content

Density Test Report

Date :04/10/2025
Project No :2025C150
Client Company :Davidson Homes
Arrival Time :04/10/2025 08:30
Onsite Hours :08:30
Name of the Project :Riverwood Retaining Wall
Project Location :Dallas
Weather :sunny
Departure Time :04/10/2025 17:00
ASEC Technician Name :Vamsi Polisetty

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
04/10/2025 1 29.6 88.0 2025-009 SP 89.2 25.2 98.7 95 D6938 Pass
Location : Lot #229 (random station next to Lot #228), Elv/Depth :third lift
Comment : Gauge Serial No. :29588
04/10/2025 2 19.9 122.5 2025-015 SP 102.8 18.1 99.4 95 D6938 Pass
Location : Lot #228, Elv/Depth :third lift
Comment : Gauge Serial No. :29588
04/10/2025 3 29.4 86.8 2025-009 SP 89.2 25.2 97.3 95 D6938 Pass
Location : Lot #228 (random station next to Lot #227), Elv/Depth :third lift
Comment : Gauge Serial No. :29588
04/10/2025 4 27.2 89.4 2025-009 SP 89.2 25.2 100.2 95 D6938 Pass
Location : Lot #227, Elv/Depth :third lift
Comment : Gauge Serial No. :29588
04/10/2025 5 28.1 88.6 2025-009 SP 89.2 25.2 99.3 95 D6938 Pass
Location : Lot #227 (random station next to Lot #226), Elv/Depth :third lift
Comment : Gauge Serial No. :29588
04/10/2025 6 26.9 87.6 2025-009 SP 89.2 25.2 98.2 95 D6938 Pass
Location : Lot #227, Elv/Depth :third lift
Comment : Gauge Serial No. :29588
04/10/2025 7 26.5 111.7 2025-009 SP 89.2 25.2 99.0 95 D6938 Pass
Location : Lot #226, Elv/Depth :third lift
Comment : Gauge Serial No. :29588
04/10/2025 8 29.1 83.0 2025-009 SP 89.2 25.2 93.0 95 D6938 Fail
Location : Lot #225 (random station in Lot #225), Elv/Depth :third lift
Comment : Moisture content well above optimum moisture. Recommended scarify, aerate and recompact. Gauge Serial No. :29588
Technician Signature / DateVamsi Polisetty, April 10, 2025