- Home
- Density Test Report Report ID: 80482
- This project is inactive from admin. Download Report
Density Test Report
Date :04/24/2025
Project No :2024C213
Client Company :WDG
Arrival Time :04/24/2025 10:00
Onsite Hours :
Name of the Project :Covington Town Center PH II
Project Location :Covington, GA
Weather :
Departure Time :04/24/2025
ASEC Technician Name :Solomon Cherie
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 04/24/2025 | 1 | 15.3 | 107.2 | ASECP001 | 106.0 | 18.2 | 101.1 | 95 | D6938 | Pass |
| Location : | Fire wall around the building, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 04/24/2025 | 2 | 17.9 | 119.5 | ASECP001 | 106.0 | 18.2 | 95.7 | 95 | D6938 | Pass |
| Location : | Fire wall around the building, Elv/Depth :1.5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. : | |||||||||
Technician Signature / DateSolomon Cherie, April 24, 2025
Reviewer Name / DateKenneth Mosman, May 04, 2025