Skip to content

Density Test Report

Date :05/09/2025
Project No :2024C213
Client Company :WDG
Arrival Time :05/09/2025 8:30
Onsite Hours :10:00
Name of the Project :Covington Town Center PH II
Project Location :Covington, GA
Weather :sunny
Departure Time :05/09/2025 18:30
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
05/09/2025 1 22.1 118.3 28586 98.7 20.6 98.2 95 D6938 Pass
Location : Retaining wall, A at station 0+25 , Elv/Depth :3.5 feet below top of wall
Comment : Gauge Serial No. :85759
05/09/2025 2 23.1 96.0 28586 98.7 20.6 97.3 95 D6938 Pass
Location : Retaining wall, A at station 0+4, Elv/Depth :3.5 feet below top of wall
Comment : Gauge Serial No. :85759
05/09/2025 3 23.1 96.8 28586 98.7 20.6 98.1 95 D6938 Pass
Location : Retaining wall, A at station 1+3, Elv/Depth :3 feet below top of wall
Comment : Gauge Serial No. :85759
05/09/2025 4 23.2 96.1 28586 98.7 20.6 97.4 95 D6938 Pass
Location : Retaining wall, A at station 0+25, Elv/Depth :1 foot below finished grade
Comment : Gauge Serial No. :85759
05/09/2025 5 20 100.9 ASECP001 106.0 18.2 95.2 95 D6938 Pass
Location : Retaining wall B at station 0+25, Elv/Depth :3 feet below top of wall,
Comment : Gauge Serial No. :85759
05/09/2025 6 20.1 121.2 ASECP001 106.0 18.2 95.2 95 D6938 Pass
Location : Retaining wall B at station 1+15, Elv/Depth :3 feet below finished grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, May 9, 2025
Reviewer Name / DateKenneth Mosman, May 15, 2025