- Home
- Density Test Report Report ID: 81840
- Edit Download Report
Density Test Report
Date :05/23/2025
Project No :2025C146
Client Company :Davidson Homes, LLC
Arrival Time :05/23/2025 13:00
Onsite Hours :
Name of the Project :Greene Farms Subdivision
Project Location :1451 Highway 113, Cartersville, Georgia
Weather :
Departure Time :05/23/2025
ASEC Technician Name :Solomon Cherie
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 05/23/2025 | 1 | 29.8 | 95.5 | ASECP002 | 99.4 | 22.4 | 96.1 | 95 | D6938 | Pass |
| Location : | Lot #16, Elv/Depth :5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 05/23/2025 | 2 | 20.3 | 90.6 | ASECP002 | 99.4 | 22.4 | 91.1 | 95 | D6938 | Fail |
| Location : | Lot #17, Elv/Depth :5 feet below finished grade | |||||||||
| Comment : | Failed, Grading For man is informed to fix. | Gauge Serial No. :30942 | ||||||||
| 05/23/2025 | 3 | 26.1 | 94.8 | ASECP002 | 99.4 | 22.4 | 95.4 | 95 | D6938 | Pass |
| Location : | Lot #18, Elv/Depth :5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 05/23/2025 | 4 | 23.8 | 95.0 | ASECP002 | 99.4 | 22.4 | 95.6 | 95 | D6938 | Pass |
| Location : | Lot #19, Elv/Depth :5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 05/23/2025 | 5 | 23.9 | 97.6 | ASECP002 | 99.4 | 22.4 | 98.2 | 95 | D6938 | Pass |
| Location : | Lot #20, Elv/Depth :5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 05/23/2025 | 6 | 16.1 | 109.5 | ASECP005 | 106.8 | 16.5 | 102.5 | 95 | D6938 | Pass |
| Location : | Lot #21, Elv/Depth :3 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 05/23/2025 | 7 | 21.1 | 104.0 | ASECP003 | 109.2 | 18.5 | 95.2 | 95 | D6938 | Pass |
| Location : | Lot #23, Elv/Depth :3 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 05/23/2025 | 8 | 17.6 | 110.6 | ASECP005 | 106.8 | 16.5 | 103.6 | 95 | D6938 | Pass |
| Location : | Lot #24, Elv/Depth :5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 05/23/2025 | 9 | 17.1 | 107.4 | ASECP005 | 106.8 | 16.5 | 100.6 | 95 | D6938 | Pass |
| Location : | Lot #25, Elv/Depth :5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 05/23/2025 | 10 | 12 | 117.3 | ASECP004 | 115.0 | 12.0 | 102.0 | 95 | D6938 | Pass |
| Location : | Lot #26, Elv/Depth :5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 05/23/2025 | 11 | 16.3 | 109.2 | ASECP003 | 109.2 | 18.5 | 100.0 | 95 | D6938 | Pass |
| Location : | Lot #27, Elv/Depth :5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 05/23/2025 | 12 | 23 | 97.7 | ASECP002 | 99.4 | 22.4 | 98.3 | 95 | D6938 | Pass |
| Location : | Lot #28, Elv/Depth :5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 05/23/2025 | 13 | 15.8 | 112.9 | ASECP004 | 115.0 | 12.0 | 98.2 | 95 | D6938 | Pass |
| Location : | Lot #29, Elv/Depth :5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 05/23/2025 | 14 | 18 | 104.2 | ASECP005 | 106.8 | 16.5 | 97.6 | 95 | D6938 | Pass |
| Location : | Lot #30, Elv/Depth :5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
Technician Signature / DateSolomon Cherie, May 23, 2025
Reviewer Name / DateKenneth Mosman, June 09, 2025