Density Test Report
Date :05/01/2025
Project No :2025C160
Client Company :Artisan
Arrival Time :05/01/2025 07:30
Onsite Hours :02:00
Name of the Project :Rockmart Township - 115 Felton Drive
Project Location :Rockmart
Weather :Overcast
Departure Time :05/01/2025 09:30
ASEC Technician Name :Sean Willett
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 05/01/2025 | 1 | 25.3 | 93.3 | 2025-012 SP | 105.6 | 18.9 | 88.4 | 95 | D2937 | Fail |
| Location : | Lot #16, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | In-situ moisture content much higher than optimum. Recommended scarification, aeration and recompaction (once weather is better). | |||||||||
| 05/01/2025 | 2 | 22.6 | 96.3 | 2025-012 SP | 105.6 | 18.9 | 91.2 | 95 | D2937 | Fail |
| Location : | Lot #18, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | In-situ moisture content much higher than optimum. Recommended scarification, aeration and recompaction (once weather is better). | |||||||||
| 05/01/2025 | 3 | 22.5 | 97.1 | 2025-012 SP | 105.6 | 18.9 | 92.0 | 95 | D2937 | Fail |
| Location : | Lot #17, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | In-situ moisture content much higher than optimum. Recommended scarification, aeration and recompaction (once weather is better). | |||||||||
Technician Signature / DateSean Willett, May 1, 2025
Reviewer Name / DateKenneth Mosman, June 23, 2025