- Home
- Density Test Report Report ID: 82182
- Edit Download Report
Density Test Report
Date :05/22/2025
Project No :2025C160
Client Company :Artisan
Arrival Time :05/22/2025 10:00
Onsite Hours :02:00
Name of the Project :Rockmart Township - 115 Felton Drive
Project Location :Rockmart
Weather :Sunny
Departure Time :05/22/2025 12:00
ASEC Technician Name :Sean Willett
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 05/22/2025 | 1 | 25.2 | 94.1 | 2025-012 SP | 105.6 | 18.9 | 89.1 | 98 | D2937 | Fail |
| Location : | Lot #80, Elv/Depth :at finished grade | |||||||||
| Comment : | In-situ moisture contents much higher than optimum moisture. Recommend scarify, aerate and recompact. | |||||||||
| 05/22/2025 | 2 | 20.8 | 100.7 | 2025-012 SP | 105.6 | 18.9 | 95.4 | 98 | D2937 | Fail |
| Location : | Lot #81, Elv/Depth :at finished grade | |||||||||
| Comment : | ||||||||||
Technician Signature / DateSean Willett, May 22, 2025
Reviewer Name / DateKenneth Mosman, June 23, 2025