Skip to content

Density Test Report

Date :06/03/2025
Project No :2025C160
Client Company :Artisan
Arrival Time :06/03/2025 13:00
Onsite Hours :03:00
Name of the Project :Rockmart Township - 115 Felton Drive
Project Location :Rockmart
Weather :sunny
Departure Time :06/03/2025 16:00
ASEC Technician Name :Sean Willett

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
06/03/2025 1 22.9 91.5 2025-012 SP 105.6 18.9 86.6 98 D2937 Fail
Location : Lot #40, Elv/Depth :at finished grade
Comment : Test results given to contractor. Recommended scarifying, aerating wet soils prior to replacement and recompaction.
06/03/2025 2 18.0 98.9 2025-012 SP 105.6 18.9 93.7 98 D2937 Fail
Location : Lot #37, Elv/Depth :at finished grade
Comment : Test results given to contractor. Recommended recompaction.
06/03/2025 3 28.5 85.5 2025-012 SP 105.6 18.9 81.0 98 D2937 Fail
Location : lot 34, Elv/Depth :finial grade
Comment : Test results given to contractor. Recommended scarifying, aerating wet soils prior to replacement and recompaction.
06/03/2025 4 23.4 88.6 2025-012 SP 105.6 18.9 83.9 95 D2937 Fail
Location : lot 127, Elv/Depth :-8
Comment : Test results given to contractor. Recommended scarifying, aerating wet soils prior to replacement and recompaction.
06/03/2025 5 18.6 95.1 2025-012 SP 105.6 18.9 90.1 95 D2937 Fail
Location : lot 129, Elv/Depth :-8
Comment : Test results given to contractor. Recommended recompaction.
Technician Signature / DateSean Willett, June 3, 2025
Reviewer Name / DateKenneth Mosman, August 04, 2025