Skip to content

Density Test Report

Date :06/05/2025
Project No :2025C160
Client Company :Artisan
Arrival Time :06/05/2025 12:00
Onsite Hours :03:00
Name of the Project :Rockmart Township - 115 Felton Drive
Project Location :Rockmart
Weather :sunny
Departure Time :06/05/2025 15:00
ASEC Technician Name :Sean Willett

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
06/05/2025 1 21.3 97.2 2025-012 SP 105.6 18.9 92.0 95 D2937 Fail
Location : Lot #133, Elv/Depth :10 feet below finished grade
Comment : Recommended recompaction prior to placement of next lift.
Technician Signature / DateSean Willett, June 5, 2025
Reviewer Name / DateKenneth Mosman, August 04, 2025