Skip to content

Density Test Report

Date :06/27/2025
Project No :2025C160
Client Company :Artisan
Arrival Time :06/27/2025 08:30
Onsite Hours :
Name of the Project :Rockmart Township - 115 Felton Drive
Project Location :Rockmart
Weather :Sunny
Departure Time :06/27/2025
ASEC Technician Name :Sean Willett

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
06/27/2025 1 14.5 91.5 0 Check
Location : Roadway, Elv/Depth :2 feet below finished grade
Comment : In-situ moisture content test
06/27/2025 2 26.4 93.6 Check
Location : Roadway, Elv/Depth :2 feet below finished grade
Comment : In-situ moisture content test
06/27/2025 6 20.7 97.9 0 Check
Location : Roadway, Elv/Depth :2 feet below finished grade
Comment : In-situ moisture content test
Technician Signature / DateSean Willett, June 27, 2025
Reviewer Name / DateKenneth Mosman, August 06, 2025