Density Test Report

Date :07/10/2025
Project No :2025C160
Client Company :Artisan
Arrival Time :07/10/2025 09:00
Onsite Hours :
Name of the Project :Rockmart Township - 115 Felton Drive
Project Location :Rockmart
Weather :Sunnt
Departure Time :07/10/2025
ASEC Technician Name :Sean Willett

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
07/10/2025 1 13.0 98.3 2025-012 SP 105.6 18.9 93.1 95 D2937 Fail
Location : Approximately Lots #156 through 158 , Elv/Depth :6 feet below finished grade
Comment : Recompaction required
Technician Signature / DateSean Willett, July 10, 2025
Reviewer Name / DateKenneth Mosman, August 07, 2025