- Home
- Density Test Report Report ID: 82991
- Edit Download Report
Density Test Report
Date :07/15/2025
Project No :2025C160
Client Company :Artisan
Arrival Time :07/15/2025 09:00
Onsite Hours :
Name of the Project :Rockmart Township - 115 Felton Drive
Project Location :Rockmart
Weather :Sunny
Departure Time :07/15/2025
ASEC Technician Name :Sean Willett
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 07/15/2025 | 1 | 21.0 | 94.3 | 2025-012 SP | 105.6 | 18.9 | 89.3 | 95 | D2937 | Fail |
| Location : | Approximately Lot #69, Elv/Depth :6 feet below finished grade | |||||||||
| Comment : | Weather affecting compaction results using cylinder ring. Will retest with a nuclear density gauge. | |||||||||
| 07/15/2025 | 2 | 19.4 | 93.7 | 2025-012 SP | 105.6 | 18.9 | 88.7 | 95 | D2937 | Fail |
| Location : | Approximately Lot #70-71, Elv/Depth :7 feet below finished grade | |||||||||
| Comment : | Weather affecting compaction results using cylinder ring. Will retest with a nuclear density gauge. | |||||||||
| 07/15/2025 | 3 | 19.4 | 95.0 | 2025-012 SP | 105.6 | 18.9 | 90.0 | 95 | D2937 | Fail |
| Location : | Approximately Lot #154, Elv/Depth :6 feet below finished grade | |||||||||
| Comment : | Weather affecting compaction results using cylinder ring. Will retest with a nuclear density gauge. | |||||||||
| 07/15/2025 | 4 | 19.3 | 100.8 | Check | ||||||
| Location : | Lot #156 and approximate area of Lot #70 area , Elv/Depth :6 feet below finished grade | |||||||||
| Comment : | Weather affecting compaction results using cylinder ring. Will retest with a nuclear density gauge. | |||||||||
| 07/15/2025 | 5 | 22.7 | 101.5 | Check | ||||||
| Location : | Lot #156 and Lot #70 area , Elv/Depth :6 feet below finished grade | |||||||||
| Comment : | Weather affecting compaction results using cylinder ring. Will retest with a nuclear density gauge. | |||||||||
| 07/15/2025 | 6 | 21.0 | 103.2 | Check | ||||||
| Location : | Lots #156 and #70, Elv/Depth :6 feet below finished grade | |||||||||
| Comment : | Weather affecting compaction results using cylinder ring. Will retest with a nuclear density gauge. | |||||||||
Technician Signature / DateSean Willett, July 15, 2025
Reviewer Name / DateKenneth Mosman, August 08, 2025