- Home
- Density Test Report Report ID: 83087
- Edit Download Report
Density Test Report
Date :07/18/2025
Project No :2025C160
Client Company :Artisan
Arrival Time :07/18/2025 08:30
Onsite Hours :
Name of the Project :Rockmart Township - 115 Felton Drive
Project Location :Rockmart
Weather :Overcast
Departure Time :07/18/2025
ASEC Technician Name :Sean Willett
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 07/18/2025 | 1 | 18.1 | 101.9 | 2025-012 SP | 105.6 | 18.9 | 96.5 | 95 | D2937 | Pass |
| Location : | Lot #72, Elv/Depth :775 | |||||||||
| Comment : | ||||||||||
| 07/18/2025 | 2 | 16.9 | 102.9 | 2025-012 SP | 105.6 | 18.9 | 97.4 | 95 | D2937 | Pass |
| Location : | Lot #73, Elv/Depth :775 | |||||||||
| Comment : | ||||||||||
| 07/18/2025 | 3 | 16.3 | 105.6 | 2025-012 SP | 105.6 | 18.9 | 100.0 | 95 | D2937 | Pass |
| Location : | Lot #74, Elv/Depth :775 | |||||||||
| Comment : | ||||||||||
| 07/18/2025 | 4 | 17.3 | 101.1 | 2025-012 SP | 105.6 | 18.9 | 95.7 | 95 | D2937 | Pass |
| Location : | Lot #75-76, Elv/Depth :775 | |||||||||
| Comment : | ||||||||||
| 07/18/2025 | 5 | 13.6 | 101.2 | 2025-012 SP | 105.6 | 18.9 | 95.8 | 98 | D2937 | Fail |
| Location : | Lot #166, Elv/Depth :at finished grade | |||||||||
| Comment : | ||||||||||
| 07/18/2025 | 6 | 15.7 | 96.2 | 2025-012 SP | 105.6 | 18.9 | 91.1 | 98 | D2937 | Fail |
| Location : | Lot #167, Elv/Depth :at finished grade | |||||||||
| Comment : | In-situ moisture content well BELOW optimum moisture. Add some moisture and recompact. | |||||||||
Technician Signature / DateSean Willett, July 18, 2025
Reviewer Name / DateKenneth Mosman, August 08, 2025