- Home
- Density Test Report Report ID: 83217
- Edit Download Report
Density Test Report
Date :07/21/2025
Project No :2024C217
Client Company :Artisan
Arrival Time :07/21/2025 09:00
Onsite Hours :06:30
Name of the Project :Naturewalk - 7 Hills Amenities
Project Location :Dallas
Weather :Mostly Cloudy
Departure Time :07/21/2025 15:30
ASEC Technician Name :Safiullah Momand
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 07/21/2025 | 1 | 1.1 | 129.3 | 2025-029MP | 129.6 | 8.5 | 99.8 | 100 | D6938 | Fail |
| Location : | Parking Lot at the right side of entrance road/ Sheally RD, Elv/Depth :at finished grade | |||||||||
| Comment : | Passed. It the time of proof rolling test Moisture and re-compaction is recommended. | Gauge Serial No. : | ||||||||
| 07/21/2025 | 2 | 1.2 | 129.7 | 2025-029MP | 129.6 | 8.5 | 100.1 | 100 | D6938 | Pass |
| Location : | Parking Lot at the right side of entrance road/ Sheally RD, Elv/Depth :at finished grade | |||||||||
| Comment : | Passed. It the time of proof rolling test Moisture and re-compaction is recommended. | Gauge Serial No. : | ||||||||
| 07/21/2025 | 3 | 1.4 | 137.9 | 2025-029MP | 129.6 | 8.5 | 106.4 | 100 | D6938 | Pass |
| Location : | Parking Lot at the right side of entrance road/ Sheally RD, Elv/Depth :at finished grade | |||||||||
| Comment : | Passed. It the time of proof rolling test Moisture and re-compaction is recommended. | Gauge Serial No. : | ||||||||
| 07/21/2025 | 4 | 1.4 | 130.2 | 2025-029MP | 129.6 | 8.5 | 100.5 | 100 | D6938 | Pass |
| Location : | Parking Lot at the right side of entrance road/ Sheally RD, Elv/Depth :at finished grade | |||||||||
| Comment : | Passed. It the time of proof rolling test Moisture and re-compaction is recommended. | Gauge Serial No. : | ||||||||
| 07/21/2025 | 5 | 1.4 | 138.1 | 2025-029MP | 129.6 | 8.5 | 106.6 | 100 | D6938 | Pass |
| Location : | Connection road to parking lot from entrance road/ Sheally RD, Elv/Depth :at finished grade | |||||||||
| Comment : | Passed. It the time of proof rolling test Moisture and re-compaction is recommended. | Gauge Serial No. : | ||||||||
| 07/21/2025 | 6 | 1.2 | 133.1 | 2025-029MP | 129.6 | 8.5 | 102.7 | 100 | D6938 | Pass |
| Location : | Connection road to parking lot from entrance road/ Sheally RD, Elv/Depth :at finished grade | |||||||||
| Comment : | Passed. It the time of proof rolling test Moisture and re-compaction is recommended. | Gauge Serial No. : | ||||||||
Technician Signature / DateSafiullah Momand, July 21, 2025
Reviewer Name / DateKenneth Mosman, August 08, 2025