Skip to content

Density Test Report

Date :07/24/2025
Project No :2025C146
Client Company :Davidson Homes, LLC
Arrival Time :07/24/2025 11:30
Onsite Hours :04:15
Name of the Project :Greene Farms Subdivision
Project Location :1451 Highway 113, Cartersville, Georgia
Weather :
Departure Time :07/24/2025 15:45
ASEC Technician Name :

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
07/24/2025 1 14 113.1 ASECP004 115.0 12.0 98.3 95 D6938 Pass
Location : Lot #42, Elv/Depth :4 feet below finished grade
Comment : Gauge Serial No. :30942
07/24/2025 2 18.1 108.9 ASECP003 109.2 18.5 99.7 95 D6938 Pass
Location : Lot #43, Elv/Depth :4 feet below finished grade
Comment : Gauge Serial No. :
07/24/2025 3 14.8 113.0 ASECP004 115.0 12.0 98.3 95 D6938 Pass
Location : Lot #44, Elv/Depth :4 feet below finished grade
Comment : Gauge Serial No. :
07/24/2025 4 10.6 118.1 ASECP004 115.0 12.0 102.7 95 D6938 Pass
Location : Lot #45, Elv/Depth :4 feet below finished grade
Comment : Gauge Serial No. :
07/24/2025 5 11.8 110.7 ASECP004 115.0 12.0 96.3 95 D6938 Pass
Location : Lot #47, Elv/Depth :4 feet below finished grade
Comment : Gauge Serial No. :
07/24/2025 6 18.8 102.1 ASECP005 106.8 16.5 95.6 98 D6938 Fail
Location : Storm line b/n MH A2 & A3, Elv/Depth :at finished grade
Comment : Failed, should be 98% b/c it is subgrade Gauge Serial No. :
07/24/2025 7 23.2 95.4 ASECP002 99.4 22.4 96.0 98 D6938 Fail
Location : Storm line b/n MH A2 & A3, Elv/Depth :at finished grade
Comment : Failed, it is in subgrade should be 98% Gauge Serial No. :
07/24/2025 8 15.2 99.0 ASECP003 109.2 18.5 90.7 98 D6938 Fail
Location : Storm line b/n MH A3 & A4, Elv/Depth :at finished grade
Comment : Failed, same as above Gauge Serial No. :
07/24/2025 9 13.2 112.7 ASECP004 115.0 12.0 98.0 98 D6938 Fail
Location : Lot #128, Elv/Depth :at finished grade
Comment : Gauge Serial No. :
07/24/2025 10 11.7 112.5 ASECP004 115.0 12.0 97.8 98 D6938 Fail
Location : Lot #130, Elv/Depth :at finished grade
Comment : Gauge Serial No. :
07/24/2025 11 11.7 115.2 ASECP004 115.0 12.0 100.2 98 D6938 Pass
Location : Lot #131, Elv/Depth :at finished grade
Comment : Gauge Serial No. :
07/24/2025 12 10.9 118.6 ASECP004 115.0 12.0 103.1 98 D6938 Pass
Location : Lot #132, Elv/Depth :at finished grade
Comment : Gauge Serial No. :
07/24/2025 13 10.9 116.2 ASECP004 115.0 12.0 101.0 98 D6938 Pass
Location : Lot #133, Elv/Depth :at finished grade
Comment : Gauge Serial No. :
Technician Signature / DateSolomon Cherie, July 24, 2025
Reviewer Name / DateKenneth Mosman, August 10, 2025