Skip to content

Density Test Report

Date :07/25/2025
Project No :2025C215
Client Company :Artisan
Arrival Time :07/25/2025 09:00
Onsite Hours :9:00
Name of the Project :NW Unit 4 Parkway Ext. Phase 1
Project Location :Dallas
Weather :Sunny
Departure Time :07/25/2025 18:00
ASEC Technician Name :Safiullah Momand

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
07/25/2025 7 24.4 92.8 2025-032 SP 94.9 25.0 97.8 98 D2937 Fail
Location : 2700 road A, Elv/Depth :0 to subgrade level
Comment :
07/25/2025 8 19.4 91.6 2025-032 SP 94.9 25.0 96.5 98 D2937 Fail
Location : 2600 road A, Elv/Depth :0 to subgrade level
Comment :
07/25/2025 9 16.3 97.1 2025-031 SP 101.0 20.7 96.1 95 D2937 Pass
Location : 2300 road A, Elv/Depth :6 feet to subgrade layer
Comment :
07/25/2025 10 14.3 99.0 2025-033 SP 104.0 16.2 95.2 95 D2937 Pass
Location : 2100 road A, Elv/Depth :8.5 feet to subgrade layer
Comment :
07/25/2025 11 18.1 96.8 2025-031 SP 101.0 20.7 95.8 95 D2937 Pass
Location : 1900 Road A, Elv/Depth :9 feet to subgrade layer
Comment :
Technician Signature / DateSafiullah Momand, July 25, 2025
Reviewer Name / DateRamchandra Mogulla, August 01, 2025