Skip to content

Density Test Report

Date :07/28/2025
Project No :2025C215
Client Company :Artisan
Arrival Time :07/28/2025 09:00
Onsite Hours :9:00
Name of the Project :NW Unit 4 Parkway Ext. Phase 1
Project Location :Dallas
Weather :Sunny
Departure Time :07/28/2025 18:00
ASEC Technician Name :Safiullah Momand

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
07/28/2025 12 13.5 96.1 2025-033 SP 104.0 16.2 92.4 95 D2937 Fail
Location : 2300 Road A, Elv/Depth :4 feet to subgrade
Comment :
07/28/2025 13 14.3 97.5 2025-033 SP 104.0 16.2 93.8 95 D2937 Fail
Location : 2100 Road A, Elv/Depth :7 feet to sub grade
Comment :
07/28/2025 14 14.9 99.2 2025-033 SP 104.0 16.2 95.4 95 D2937 Pass
Location : 2300, Elv/Depth :1 feet to subgrade
Comment :
07/28/2025 15 11.1 98.0 2025-033 SP 104.0 16.2 94.2 95 D2937 Fail
Location : 1900, Elv/Depth :8 feet to sub grade
Comment :
Technician Signature / DateSafiullah Momand, July 28, 2025
Reviewer Name / DateRamchandra Mogulla, August 01, 2025