- Home
- Density Test Report Report ID: 84175
- Edit Download Report
Density Test Report
Date :08/11/2025
Project No :2025C160
Client Company :Artisan
Arrival Time :08/11/2025 08:30
Onsite Hours :
Name of the Project :Rockmart Township - 115 Felton Drive
Project Location :Rockmart
Weather :Overcast
Departure Time :08/11/2025
ASEC Technician Name :Sean Willett
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 08/11/2025 | 1 | 21.0 | 94.6 | 2025-012 SP | 105.6 | 18.9 | 89.6 | 95 | D2937 | Fail |
| Location : | Roadway near Lots #188 and #189, Elv/Depth :799 | |||||||||
| Comment : | The onset of rain may have affected these moisture test results. Testing was discontinued after the onset of rain. | |||||||||
Technician Signature / DateSean Willett, August 11, 2025
Reviewer Name / DateKenneth Mosman, August 12, 2025