Skip to content

Density Test Report

Date :08/11/2025
Project No :2025C160
Client Company :Artisan
Arrival Time :08/11/2025 08:30
Onsite Hours :
Name of the Project :Rockmart Township - 115 Felton Drive
Project Location :Rockmart
Weather :Overcast
Departure Time :08/11/2025
ASEC Technician Name :Sean Willett

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
08/11/2025 1 21.0 94.6 2025-012 SP 105.6 18.9 89.6 95 D2937 Fail
Location : Roadway near Lots #188 and #189, Elv/Depth :799
Comment : The onset of rain may have affected these moisture test results. Testing was discontinued after the onset of rain.
Technician Signature / DateSean Willett, August 11, 2025
Reviewer Name / DateKenneth Mosman, August 12, 2025