- Home
- Density Test Report Report ID: 85153
- Edit Download Report
Density Test Report
Date :09/04/2025
Project No :2025C146
Client Company :Davidson Homes, LLC
Arrival Time :09/04/2025 10:00
Onsite Hours :
Name of the Project :Greene Farms Subdivision
Project Location :1451 Highway 113, Cartersville, Georgia
Weather :
Departure Time :
ASEC Technician Name :Solomon Cherie
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 09/04/2025 | 1 | 14.4 | 91.5 | ASECP003 | 109.2 | 18.5 | 83.8 | 95 | D2937 | Fail |
| Location : | Lot #53, Elv/Depth :4.5 feet below finished grade | |||||||||
| Comment : | Recompaction required. | |||||||||
| 09/04/2025 | 2 | 21.6 | 88.9 | ASECP002 | 99.4 | 22.4 | 89.4 | 95 | D2937 | Fail |
| Location : | Lot #55, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Recompaction required. | |||||||||
| 09/04/2025 | 3 | 18.0 | 93.9 | ASECP005 | 109.2 | 18.5 | 86.0 | 95 | D2937 | Fail |
| Location : | Lot #58, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | All failing tests were reported to the contactor. Recommended scarifying and recompacting prior to retesting. | |||||||||
Technician Signature / DateSolomon Cherie, September 4, 2025
Reviewer Name / DateKenneth Mosman, October 15, 2025