Skip to content

Density Test Report

Date :09/04/2025
Project No :2025C146
Client Company :Davidson Homes, LLC
Arrival Time :09/04/2025 10:00
Onsite Hours :
Name of the Project :Greene Farms Subdivision
Project Location :1451 Highway 113, Cartersville, Georgia
Weather :
Departure Time :
ASEC Technician Name :Solomon Cherie

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
09/04/2025 1 14.4 91.5 ASECP003 109.2 18.5 83.8 95 D2937 Fail
Location : Lot #53, Elv/Depth :4.5 feet below finished grade
Comment : Recompaction required.
09/04/2025 2 21.6 88.9 ASECP002 99.4 22.4 89.4 95 D2937 Fail
Location : Lot #55, Elv/Depth :4 feet below finished grade
Comment : Recompaction required.
09/04/2025 3 18.0 93.9 ASECP005 109.2 18.5 86.0 95 D2937 Fail
Location : Lot #58, Elv/Depth :4 feet below finished grade
Comment : All failing tests were reported to the contactor. Recommended scarifying and recompacting prior to retesting.
Technician Signature / DateSolomon Cherie, September 4, 2025
Reviewer Name / DateKenneth Mosman, October 15, 2025